Rotork Fairchild Products Model 4500A Pneumatic 1:1 Volume Booster, 3/4 FPT line, 1/4 FPT signal, 1/4 FPT gauge, 250psig [17 BAR] max, 150psig [10 BAR] max output, 150 SCFM @ 100 psig/20psig set, 0.5 psi accy, Nitrile on Dacron, tapped exhaust, SS trim.
Browse All Fairchild Products Products
Browse All Model 4500A Products
Manufacturer: Fairchild Products
Accuracy: 0.50 Psi
Ambient Temperature: -40° To 200 °F (-40° To 93.3 °C)
Base Model: 4516A
Body Material: Aluminum
Elastomer: Nitrile On Dacron
Exhaust Capacity: 40 SCFM [65.2m³/Hr] Where Downstream Pressure Is 5 Psi Above 20 Psi Setpoint
Exhaust Type: [E] Tapped Exhaust 1/2 FPT
Flow Capacity: 150 SCFM
FlowCv: 3
Mounting: Wall (20555-1 Bracket Required)
Operator: Pneumatic Pilot Signal
Options: [E] Tapped Exhaust [S] SS Trim
Pipe Size: 3/4 FPT
Pressure Range: 0 To 150 Psi
Product Type: Pneumatic Volume Boosters
Ratio: 1:01
RatioAccuracy: 3.0% Of 100 Psi Output Span
Sensitivity: 1 In. WC
Supply Pressure: 250 Psi
Product Category: Pneumatic Volume Boosters
The Rotork Fairchild Model 4500 Model 4500 Pneumatic Volume Booster is popular due to rugged design and high flow capacity in an economical package. With its pilot operated regulator design, the M4500 handles up 250 psig [17 BAR] (1700 kPa) supply pressure and has five available signal to output ratios to meet most control element requirements. The 4500 Booster provides a flow capacity of 150 SCFM [255m3/Hr], which equates to a Cv factor of approximately 3.0 in both forward and exhaust modes.
Extremely fast and responsive operation
Versatility to meet most control element requirements
Allows use in precision applications
Minimizes air consumption
Isolates the diaphragm from the main flow to eliminate hunting and buzzing
Minimizes pressure drop at final control element under flow conditions
Allows tuning for optimum dynamic response (1:1 ratio only) and cycle free operation with valve positioners
Eliminates any hunting and buzzing
Certification for use in all Canadian territories and provinces
NOTES: Oil free air must be applied to the regulator. Use a filter to remove dirt and entrained liquid in the air line ahead of the regulator. If an air line lubricator is used, it MUST be located downstream of the regulator, to avoid interference with regulator performance.